- Air Power Equipment
- Bristol Air Compressor
- Portable Screw Air Compressor
- Other Air Compressors
- Drill Rig
- Drilling Machine
- Jack Hammer
- Alloy Cables
- Pyroelectric Infrared Sensor
- Compressed Air Drying Machine
- Generator Sets
- Diesel Generator Set
- Special Generating Sets
- Heavy Oil Generator Set
- Gas Generator Set
- High Voltage Generator
- Soundproof Diesel Generator
- Silent Diesel Generator
- Three-Phase Diesel Generator
- Stationary Diesel Generating Sets
- Marine Diesel Generating Sets
- Trailer Mounted Diesel Generator Set
- Truck Diesel Generator Set
- Mobile Diesel Generator Set
- Standby Diesel Generator Set
- Emergency Diesel Generator Set
- Automatic Diesel Generating Set
- Automatic Start Diesel Generating Sets
- AC Diesel Generator Set
- DC Diesel Generator Set
- Construction Hoisting Machinery
- Crushing Plant
- Mucking Loader
High Voltage Generator
Description
High voltage generator set is composed of diesel engine, generator, start motor, elastic coupling and supporting base. It is powered by famous brand diesel both at home and abroad. According to GB2820 General Technical Requirements of Industrial Frequency Diesel Generating Sets and with reference to IEC34-I standard, we adopt high quality high voltage diesel generator series (6300 V, 10500 V). High voltage generator set plays great important role in large-scale data centers in industries like finance, insurance, communication and education industry.
Advantages
With the advantage of far output distance and little loss, high voltage generator set can provide back-up source for data center, avoiding entire power failure and guaranteeing continuous data transmission.
Features
1. High voltage generator set is characterized by regulating voltage accuracy and good dynamic property.
2. High voltage diesel generator features small voltage wave distortion, high efficiency, reliable operation and convenient maintenance.
3. High voltage generator set has compact structure and long service life.
Parameters
Model | Aggregate Capacity (Kw) | Rated Current (A) | Diesel Model | Diesel Power | Cylinder Diameter (mm) | Stroke (mm) | Gas Displacement (L)x | Oil Consumption (g/Kw.h) | 100% Load Specific Fuel Consumption (g/Kw.h) | ||
6300V | 400V | 10500V | |||||||||
B1000GF | 1000 | 114.6 | 1804 | 68.7 | G6300ZD | 1125 | 300 | 380 | 161 | 2.16 | 204 |
B1250GF | 1250 | 143.2 | 2255 | 85.9 | G8300ZD | 1500 | 300 | 380 | 215 | 2.16 | 204 |
B1600GF | 1600 | 13 | 2886.7 | 110 | G8300ZD13 | 1765 | 300 | 380 | 215 | 2.16 | 204 |
B2000GF | 2000 | 229 | 3608 | 137.5 | G8300ZD16 | 2206 | 300 | 380 | 215 | 2.16 | 204 |
Operating Attention
1. Users should strictly abide by the operation and maintenance specification of high voltage generator set and start up high voltage diesel generator regularly for ten to fifteen minutes for no-load test.
2. The operators should be familiar with high voltage generator set operation standard and be qualified for such operation procedure.
3. Relevant high voltage safeguard procedures are available in parallel operation and switchgear machine room. Operators must strictly follow operating procedures to run high voltage diesel generator.
1) Switchgear is equipped with reliable mechanical and electric interlock mechanism, in line with the requirements of “Five-Protection” function, so as to guarantee the correct operation of switchgear and trolley is procedural.
(1) There is a suggestive button or KK type change-over switch on the door of control room so as to avoid switching on or off the disconnector improperly.
(2) Only when tested or in working position can disconnector trolley be switched on or off. If the disconnector is switched on, the trolley cannot move, which avoids on-load pushing-pulling circuit breaker inappropriately.
(3) Only if the earthing switch is in the open position, the circuit breaker can move from testing\breaking position to working position. Only if the circuit breaker is in testing\breaking position, the earthing switch can be switched to the open position.
(4) When the earthing switch is in the open position, the bottom door and back door cannot be open, avoiding straying into charged intervals.
(5) If circuit breaker handcart is indeed in the test or work position, and there is no control voltage, it can only be manual braked, but not be switched on.
2) If throlley is in the work position, second plug is locked and cannot be removed.
3) Disconnector can be separated with trolley. The busbar should be isolated from feeder circuit.
4) All the operation of high voltage generator set can be carried out when the switchgear panel is closed.
5) Switch cabinet and all metal partitions should be connected to the ground. Earth conductor is mounted inside switchgear.
6) Enclosure protection grade reaches IP4X, which can effectively prevent the human body and the solid from approaching the live part and touching the moving parts and can protect the personal safety and guarantee reliable operation.
Payment: T/T or L/C at sight
Mode of Transportation: By Motor in China, By Sea Abroad
Bristol Compressors (Shanghai) Co., Ltd. is specialized in manufacturing high voltage generator set (high voltage diesel generator) for sale. With the quick development of generator sets, production bases and representative offices are founded throughout the world, such as China, U.S.A, Germany, France, Japan, Holland and Belgium, etc. For detailed information about high voltage generator set, please enter our home page or contact us directly.